The Use of Stainless Steel in Metal Stair Fabrication
The Use of Aluminum in Metal Stair Fabrication

Stair Head Clearance Code (OSHA Minimum Overhead Clearance)

Stair head clearance is the vertical space between a stair tread (or its nosing) and the nearest overhead obstruction. The minimum head clearance for most stairs is 80 inches (6 feet 8 inches, 2032 mm) under OSHA, the International Building Code (IBC) and the International Residential Code (IRC). These codes ensure stair headroom is adequate for the vast majority of users to walk without hitting obstructions or protrusions in the walkway.

Minimum head clearance for stairs

The minimum head clearance for stairs under IBC and OSHA is 80 inches (2032 mm) above the stair tread to any overhead obstruction or protrusion from the ceiling. Stair headroom clearance is measured vertically from the leading edge of the stair tread, or the nosing.

Diagram showing 80-inch minimum head clearance measured vertically from the stair tread nosing to the ceiling

Minimum stair head clearance: 80″ measured vertically from the tread nosing.

Minimum stair head clearance by code and stair type
Stair type or area Minimum head clearance Code reference
Standard stairs (industrial/workplace) 6 ft 8 in (80 in, 203 cm) OSHA 1910.25(b)(2)
Standard stairs (commercial) 80 in (2032 mm) IBC 1011.3
Stair landings 80 in (2032 mm), full width of stair and landing IBC 1011.3
Spiral stairs 6 ft 6 in (78 in, 1.98 m) OSHA 1910.25(d)(3); IBC 1011.3 exception
Door closers and stops in a stairway 78 in (1981 mm) IBC 1003.3.1 exception
Exit route ceiling 7 ft 6 in (2.3 m); projections no lower than 6 ft 8 in (2.0 m) OSHA 1910.36(g)(1)
Means of egress (fire exits) 7 ft 6 in (2285 mm); projections no lower than 6 ft 8 in (2030 mm) NFPA 101 7.1.5
Stairs and landings in means of egress 6 ft 8 in (2030 mm) NFPA 101 7.1.5.3
Residential and basement stairs 6 ft 8 in (2032 mm) IRC R311.7.2
Alternating tread stairs to roof hatches (recommended) 88.2 in at 56°; 108.7 in at 68° Lapeyre Stair recommendation (code minimum is 80 in)

OSHA stair head clearance requirements

OSHA requires at least 6 feet 8 inches (203 cm) of vertical clearance above any stair tread, measured from the leading edge of the tread. The requirement is in OSHA 1910.25 – Stairways:

1910.25(b)(2) Vertical clearance above any stair tread to any overhead obstruction is at least 6 feet, 8 inches (203 cm), as measured from the leading edge of the tread.

This headroom clearance applies to all types of stairway design and applications, whether standard stairs, alternating tread stairs, prefab commercial stairs, egress stairs, metal stairs, or wood stairs.

The OSHA head clearance also applies to exit stairs that are part of an exit route. OSHA section 1910.36(g)(1) requires that the ceiling of an exit route be at least 7 feet 6 inches (2.3 m) high, and any projection from the ceiling must not reach a point less than 6 feet 8 inches (2.0 m) from the floor.

IBC minimum stair head clearance code

The IBC requires a minimum stair headroom of 80 inches (2032 mm), measured vertically from a line connecting the edges of the nosings. IBC is the most widely adopted commercial building code for stairs, and its headroom rule is in IBC 2018 Section 1011.3 Headroom:

Stairways shall have a headroom clearance of not less than 80 inches (2032 mm) measured vertically from a line connecting the edge of the nosings. Such headroom shall be continuous above the stairway to the point where the line intersects the landing below, one tread depth beyond the bottom riser. The minimum clearance shall be maintained the full width of the stairway and landing.

Other stair head clearance code rules

Roof hatches, door closers and stops, and spiral stairs have their own head clearance rules or recommendations.

Diagram of recommended head clearance for alternating tread stairs to a roof hatch: 88.2 inches at 56 degrees and 108.7 inches at 68 degrees

Recommended roof hatch head clearance for alternating tread stairs: 88.2″ at 56° and 108.7″ at 68°.

Roof hatch headroom clearance

Alternating tread stairs used for roof access require the same 80 inches of headroom, but Lapeyre Stair recommends more because of their steeper angle. Steep stairs like alternating tread stairs are often used for IBC roof access under IBC 1011.3. We recommend a minimum head clearance of 88.2 inches for 56° alternating tread stairs and 108.7 inches for 68° alternating tread stairs.

Door closer headroom clearance

Door closers and stops in a stairway may reduce headroom to no less than 78 inches (1981 mm), under the exception to IBC 1003.3.1. This is one of the few special exceptions to the minimum headroom requirements.

Like stairways, ramps and ramp landings also require 80 inches of head clearance.

Diagram of spiral stair head clearance showing a 78-inch minimum

Spiral stairs are permitted 78″ of head clearance.

Spiral minimum stair head clearance

Spiral stairs need at least 78 inches (6 feet 6 inches) of head clearance, 2 inches less than other stair types under both OSHA and IBC.

Per OSHA 1910.25(d)(3), spiral stairs must meet the vertical clearance requirement of 6 feet 6 inches (1.98 m).

Under the exception to IBC 1011.3 Headroom, spiral stairways are permitted a 78-inch (1981 mm) headroom clearance.

Basement stair clearance height

Basement stairs generally need 6 feet 8 inches of headroom, as required by IRC section R311.7.2 Headroom.

There is one special exception for bulkhead enclosure stairways. IRC section R311.7.10.2 exempts stairways serving bulkhead enclosures from the requirements of Sections R311.3 and R311.7 when all of these conditions are met:

  • The stairway is not part of the required building egress.
  • It provides access from the outside grade level to the basement.
  • The height from the basement finished floor level to grade adjacent to the stairway is not more than 8 feet (2438 mm).
  • The grade level opening to the stairway is covered by a bulkhead enclosure with hinged doors or other approved means.

Fire stairs headroom

Fire stairs need at least 6 feet 8 inches (2030 mm) of headroom under NFPA 101, and the same 80 inches applies under OSHA and IBC. Fire stairs are stairs that are part of a means of egress or an exit route from a building under IBC, NFPA, or OSHA.

Fire stairs headroom is defined in NFPA 101 Chapter 7 Means of Egress, section 7.1.5.3: headroom on stairs and stair landings must be not less than 6 feet 8 inches (2030 mm), measured vertically above a plane parallel to, and tangent with, the most forward projection of the stair tread.

How much clearance do fire exits need?

Fire exits need 7 feet 6 inches (2285 mm) of ceiling headroom, with ceiling projections no lower than 6 feet 8 inches (2030 mm), under NFPA 101 Section 7.1.5 Headroom. A tolerance of 3/4 inch is allowed for projections.

The minimum headroom for stairs in a fire exit is the same 80 inches under OSHA, IBC, and NFPA.

Diagram showing 80-inch head clearance maintained over the stairway and the landing

The 80″ minimum head clearance applies over both the stairway and the landing.

Headroom clearance for a landing

A stair landing needs the same 80 inches of headroom as the stairway. IBC Section 1011.3 Headroom states that the minimum clearance must be maintained the full width of the stairway and the landing.

The OSHA stair landing clearance code is not explicitly stated, but can be interpreted as the same 80 inches as for a stairway, because the definition of a stairway in section 1910.21 includes any landings and platforms between the risers and treads.

Residential stair head clearance

Residential stairs need at least 6 feet 8 inches (2032 mm) of headroom under the International Residential Code (IRC). Section R311.7.2 Headroom measures this vertically from the sloped line adjoining the tread nosings, or from the floor surface of the landing or platform on that portion of the stairway.

Final points on stair head clearance

Stair building codes establish the minimum staircase clearance for headroom. Identifying and preventing areas of low stair head clearance should be part of a routine OSHA walking working surface assessment in your safety program. By ensuring stairs meet these headroom requirements, safety managers, stair designers and installers can create a safe stair walking experience and reduce the chance of injuries on stairs.

FAQs on stair headroom clearance

Which type of stairs is best for head clearance?

Any stair that meets the 80-inch minimum head clearance required by OSHA, the IBC and the IRC is acceptable. Generally, the less steep the stair, the less chance that the minimum headroom clearance will be violated.

How do you measure headroom?

Measure headroom in a vertical line from the finished floor surface to the ceiling or to the lowest object protruding from it. On a stairway, headroom is measured vertically from a line connecting the edges of the nosings, or from the leading edge of the stair tread.

Recent Posts

RCA-scaled
Lapeyre Alternating Tread Stair recognized as Best 'Tried & True,' 'Structural & Core System' product
stainless steel alternating tread stair
The Use of Stainless Steel in Metal Stair Fabrication
aluminum-diamond-plate-resized
The Use of Aluminum in Metal Stair Fabrication

Reach Out

Ready To Take The Next Step?