Roof access requirements depend on whether the roof is occupied. Under the IBC, occupied roofs must be reached by a stairway, while unoccupied roofs may be reached through a roof hatch by an alternating tread stair, a ships ladder, or a permanent ladder. Understanding the IBC stair requirements and OSHA stair requirements for roof access, and the usability and safety of each type of device, will help you choose the right device for accessing roof hatches and unoccupied rooftop spaces. In certain circumstances, alternating tread stairs, ship stairs, and permanent ladders may be used to access unoccupied roofs through roof hatches.
| Roof type or use | Permitted access device | Code reference |
|---|---|---|
| Occupied roof | Stairway through a penthouse | IBC 1011.12, 1011.12.2, 1510.2 |
| Unoccupied roof | Alternating tread device, ships ladder, or permanent ladder; roof hatch or trap door permitted | IBC 1011.12 and 1011.12.2 exceptions |
| Roof with elevator equipment | Stairway | IBC 1011.12.1 |
| Equipment or maintenance access (not egress) | OSHA-compliant stairs or ladders; alternating tread, ship or spiral stairs only where standard stairs are not feasible | OSHA 1910.23, 1910.25(b)(8) |
Table of contents
- Occupied roofs vs unoccupied roofs
- Roof access applications
- Occupied roof egress requirements
- Unoccupied roof egress requirements
- IBC roof access requirements
- IBC roof access ladder requirements
- IBC roof access requirements for stairs
- IBC roof access hatch code requirements
- OSHA roof access requirements
- OSHA roof ladder access requirements
- OSHA roof stair requirements
- OSHA rooftop crossover stair requirements
- OSHA roof access hatch requirements
- Stair vs ladder for unoccupied roof access
IBC and OSHA requirements for occupied roofs vs unoccupied roofs
The IBC treats occupied roofs, which the public can use, differently from unoccupied roofs, which only maintenance or construction workers access. The means of egress definition is the same for both, but the requirements differ because the two types of roofs have different uses and occupancy types.
Occupied roof definition
An occupied roof is a roof accessible to building occupants, such as a rooftop lounge, swimming pool, or other roof assembly area open to the general public. It is considered a story within the building like any other enclosed story, so the same means of egress requirements apply.
Unoccupied roof definition
An unoccupied roof is accessible only to maintenance or construction workers, who may need to service the roof itself or mechanical equipment located on it.
Roof access applications
Roof access applications fall into three main groups:
- Egress from or to occupied roofs
- Access to unoccupied roof areas
- Exterior access to rooftop equipment or roof elevation changes
IBC requirements for occupied roof egress
Egress to an occupied roof must be through a stairway that meets all the requirements of IBC stairway design. The stairway to the roof must also be through a penthouse complying with IBC section 1510.2. As a result, stairway access to occupied roofs is typically an extension of the exit stairways up to the roof.
IBC requirements for unoccupied roof egress
Unoccupied roofs may be accessed from the top story by an alternating tread device, a ships ladder, or a permanent ladder, under the exception to IBC 1011.12.
The exception to IBC 1011.12.2 also allows access to unoccupied roofs to be through a roof hatch or trap door. So for unoccupied roofs, a ladder or alternating tread stair extending through a roof hatch is the most common method of accessing the roof.
IBC requirements for roof access
The IBC requires one stairway to extend to the roof in buildings of four or more stories, unless the roof is steeper than a 4:12 slope. Roof access requirements are found in 2018 IBC section 1011.12, Stairway to Roof:
In buildings of four or more stories above grade plane, one stairway shall extend to the roof surfaces unless the roof has a slope steeper than four units vertical in 12 units horizontal (33 percent slope).
Exception: Other than where required by Section 1011.12.1, in buildings without an occupied roof access to the roof from the top story shall be permitted to be by an alternating tread device, a ships ladder or a permanent ladder.

Alternating tread stair accessing a roof hatch
Section 1011.12.1, Stairway to elevator equipment, requires a stairway where roofs and penthouses contain elevator equipment that must be accessed for maintenance.
IBC Section 1011.12.2, Roof access:
When a stairway is provided to a roof, access to the roof shall be provided through a penthouse complying with Section 1510.2.
Exception: In buildings without an occupied roof, access to the roof shall be permitted to be a roof hatch or trap door not less than 16 square feet in area and having a minimum dimension of 2 feet.
In summary, occupied roofs require access by a stairway, and unoccupied roofs can be accessed by an alternating tread stair, ships ladder or permanent ladder through a roof hatch. For unoccupied roof applications, alternating tread stairs are the safest and easiest to use solution because the user has a full tread depth to rest on at each step. The video below compares an alternating tread stair with a ships ladder.
IBC roof access ladder requirements
Permanent ladders may access unoccupied roofs that are not required to have a stairway, but they cannot serve as a means of egress from occupied spaces. Ladders, ships ladders and alternating tread stairs accessing unoccupied roofs must meet all the design requirements of the relevant IBC section. IBC 1011.16, Ladders, states:
Permanent ladders shall not serve as part of the means of egress from occupied spaces within a building. Permanent ladders shall be constructed in accordance with Section 306.5 of the International Mechanical Code.
See our inventory of roof access stairs.
IBC roof access code requirements for stairs
Stairways for roof access must meet all the design requirements in IBC 1011. For occupied roofs, stairways are required as a means of egress. For unoccupied roofs, alternating tread stairs or ladders can be used in place of stairways.
IBC rooftop crossover stairs requirements
Rooftop crossover stairs generally do not need to meet IBC stairway design criteria because they are used for equipment or maintenance access, not as a means of egress, and are not accessible to the general public. They do need to comply with all OSHA and/or International Mechanical Code requirements.
IBC roof access hatch code requirements
Under the IBC, a roof hatch for an unoccupied roof must be at least 16 square feet in area with a minimum dimension of 2 feet. This requirement is in the exception to section 1011.12.2:
Exception: In buildings without an occupied roof, access to the roof shall be permitted to be a roof hatch or trap door not less than 16 square feet in area and having a minimum dimension of 2 feet.
Roof hatches accessed by alternating tread stairs or ships stairs must also be large enough to meet the IBC and OSHA head clearance requirements. The minimum head clearance is 80″ per IBC 1011.3. The opening size depends on the angle of the stair.

Roof hatch opening size depends on stair angle and headroom clearance
| Alternating tread stair angle | Minimum hatch size |
|---|---|
| 56° | 2’6″ x 6’0″ |
| 68° | 2’6″ x 4’6″ |
OSHA requirements for roof access
OSHA roof access requirements apply to all stairs and ladders used for equipment or maintenance access that are not used as a means of egress. Access devices for these applications fall under the International Mechanical Code rules for equipment on roofs or the OSHA design standards for stairs and ladders. OSHA has many requirements for ladder and stair design but only two general requirements for how stairs and ladders should be applied:
- 1910.23(b)(8) Ladders are used only for the purposes for which they were designed;
- 1910.25(b)(8) Spiral, ship, or alternating tread-type stairs are used only when the employer can demonstrate that it is not feasible to provide standard stairs.
OSHA leaves it to the employer to ensure that the use of a stair or ladder is safe and appropriate in each application, so employers must understand the safety, feasibility, and usability of stairs and ladders in different applications.
OSHA roof access ladder requirements
OSHA regulates roof ladders under 1910.23, Ladders, and treats permanent roof ladders for regular maintenance as fixed ladders:
- Fixed ladder
- A ladder with rails or individual rungs that is permanently attached to a structure, building, or equipment. Fixed ladders include individual-rung ladders, but not ship stairs, step bolts, or manhole steps.
OSHA defines three types of fixed ladders that may be used for permanent roof access:
- Side-step ladder
- A fixed ladder that requires an employee to step sideways from it in order to reach a walking-working surface, such as a landing.
- Through ladder
- A fixed ladder that allows the employee to step through the side rails at the top of the ladder to reach a walking-working surface, such as a landing.
- Individual-rung ladder
- A ladder that has rungs individually attached to a building or structure.

OSHA 1910.23 Figure D-4
Employers must ensure that all ladders comply with the design requirements of section 1910.23(b). Permanent fixed roof ladders must also comply with section 1910.23(d), which covers all fixed ladder systems.
OSHA roof ladder fall protection requirements
Fixed roof access ladders must have proper fall protection under OSHA 1910.28. Section 1910.28(b)(1)(i) requires that each employee on a walking-working surface with an unprotected side or edge 4 feet (1.2 m) or more above a lower level is protected by one or more of the following:
- 1910.28(b)(1)(i)(A) Guardrail systems;
- 1910.28(b)(1)(i)(B) Safety net systems; or
- 1910.28(b)(1)(i)(C) Personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems.
| Section | Ladder status | Required protection |
|---|---|---|
| 1910.28(b)(9)(i)(A) | Existing fixed ladders installed before November 19, 2018 | Personal fall arrest system, ladder safety system, cage, or well |
| 1910.28(b)(9)(i)(B) | New fixed ladders installed on and after November 19, 2018 | Personal fall arrest system or ladder safety system |
| 1910.28(b)(9)(i)(C) | Replacement of a fixed ladder, cage, or well, or any portion of a section | Personal fall arrest system or ladder safety system in at least the section where the replacement is located |
| 1910.28(b)(9)(i)(D) | All fixed ladders on and after November 18, 2036 (final deadline) | Personal fall arrest system or ladder safety system |
OSHA roof access stair requirements
OSHA roof stairs follow the same rules as any other OSHA stairs, found in 1910.25, Stairways. Typical OSHA roof access applications include reaching different elevations on a roof and accessing rooftop equipment.

Alternating tread stair used to access a change in roof elevation

Alternating tread stair for rooftop AHU equipment access
OSHA rooftop crossover stair requirements
OSHA rooftop crossover stairs must meet the same design requirements as all other OSHA stairs and platforms. For roof parapets or equipment crossovers, standard stair crossover systems may be used, or alternating tread stair crossovers where there is not room for a standard stair crossover.

Rooftop crossover stair
OSHA roof access hatch requirements
To meet OSHA standards, a roof hatch must be large enough to provide the minimum clearances in section 1910.23 for ladders and 1910.25 for stairways.
1910.23(d)(13)(ii) A minimum perpendicular distance of 30 inches (76 cm) from the centerline of the steps or rungs to the nearest object on the climbing side. When unavoidable obstructions are encountered, the minimum clearance at the obstruction may be reduced to 24 inches (61 cm), provided deflector plates are installed.
The roof hatch opening must be large enough to provide the 30-inch clearance from the ladder rung to the roof obstruction, or a deflector plate must be installed.

OSHA 1910.23 Figure D-5 ladder clearances
For stairways, section 1910.25(b)(2) requires vertical clearance above any stair tread to any overhead obstruction of at least 6 feet, 8 inches (203 cm), measured from the leading edge of the tread.
Roof hatches accessed by alternating tread stairs or ships ladders must be large enough to meet the headroom clearance requirements, so the opening size depends on the stair angle. The minimum hatch sizes in the table above apply: 2’6″ x 6’0″ for a 56° alternating tread stair and 2’6″ x 4’6″ for a 68° alternating tread stair.
Stair vs ladder for roof access
Choose a stairway over a ladder for roof access whenever possible, because stairs are safer, more comfortable and more efficient for workers. For many years, fixed ladders were the standard device for unoccupied roof access, but the CDC estimates that approximately 20% of fall injuries involve falls from ladders and recommends providing alternative, safer equipment for extended work at elevation.
OSHA also recognizes the danger of caged ladders. The 2017 update to the Walking-Working Surfaces standards requires ladder safety systems on all ladders that extend more than 24 feet above a lower level, and cages are no longer allowed as a ladder safety system. OSHA also requires that:
- 1910.23(b)(11) Each employee faces the ladder when climbing up or down it;
- 1910.23(b)(12) Each employee uses at least one hand to grasp the ladder when climbing up and down it; and
- 1910.23(b)(13) No employee carries any object or load that could cause the employee to lose balance and fall while climbing up or down the ladder.
Because of these requirements, maintenance workers must rope tools and service equipment up and down rather than carry them, which makes ladders burdensome. Stairway systems can be used for all roof access applications:
- Roof hatch access
- Accessing a roof from the ground
- Accessing different elevations of a roof system
- Accessing equipment on rooftops
- Crossover stairs over a roof parapet
Choosing a roof access device
Start by determining whether the roof is occupied: occupied roofs require a stairway, while unoccupied roofs can use an alternating tread stair, ships ladder or permanent ladder. Whenever possible, choose a stairway as a safer alternative to ladders. For unoccupied roof access through a roof hatch, or for space-confined rooftop equipment access, alternating tread stairs are the safest, easiest to use solution.
FAQ
Is roof access required by code?
Yes, the 2018 IBC requires roof access for buildings of four or more stories. Occupied roofs require access by a stairway. Unoccupied roof access can be by an alternating tread device, a ships ladder or a permanent ladder.
What is an occupied roof?
An occupied roof is a rooftop accessible to the general public for use as a lounge area, swimming pool or other assembly area. It is considered a story within the building and must be provided with a stairway as a means of egress.
What is a roof hatch used for?
A roof hatch provides safe access to an unoccupied rooftop in commercial buildings. The IBC permits roof hatches or trap doors for unoccupied rooftop areas so service personnel can perform building and equipment maintenance.